WHO IS? WOYZECK TECHNICAL REQUIREMENTS duration of performance: 100 minutes without interval company members [performers 3 + others 2] -------------------------------------------------------------------------------------------------------------------------------- STAGE SPECIFICATIONS [optimal circumstances, contact us if you have difficulties] A. SETTING Black-box theatre or Open air venues are suitable. B. PERFORMING AREA Stage [INDOOR] or empty flat space [OUTDOOR]: ideal 12 X 12 m / min. 10 X 10 m Flat floor > Black dance floor in good condition [if necessary the Company provides one] No backdrop nor masking > No need for fixing things into the floor > No use of fire nor of water > No use of projection -------------------------------------------------------------------------------------------------------------------------------- DESCRIPTION OF THE STAGE ELEMENTS [provided by PERFORMINGUNIT] A/ 3 chairs with sound speakers B/ plastic cover for the floor -------------------------------------------------------------------------------------------------------------------------------- SOUND [to be provided by presenter] the music and sound effects are on 2 CDs - Mixing console [min. 16 inputs] - 01 quality microphone - 02 quality CD players [if necessary the Company provides one] - a high quality amplification system adapted to the volume of the theatre or site-specific location - PA surround loudspeakers [04] + on-stage monitors [04] -------------------------------------------------------------------------------------------------------------------------------- LIGHT [to be provided by presenter] - 01 control [manual] desk with a minimum of 12 masters [must be placed on stage next to the sound board] - 25 PCs [on 4 light bars forming a general wash over the entire performing area] - 12 Profiles - 06 Fresnels 1 KW - All Filters Lee numbers: 728,725,202 for pc 017,013,724 for profile -------------------------------------------------------------------------------------------------------------------------------- A. SCHEDULE REQUIREMENTS load-in 15 min. > set-up time: approx. 4 h > performance:100 min. without intermission > strike: 30 min. > load-out: 15 min. B. CREW REQUIREMENTS IMPORTANT: The performance is not accompanied by technician/s. Light and sound desk during the performance are operated by the Director/Assistant. 1 day prior to the performance: a/ load-in > 1 person b/ set-up > stage elements 1 person > lights 1 light technician > sound 1 sound engineer c/ focusing > 1 light technicians d/ rehearsal day of the performance a/ light check b/ sound check c/ spacing during the performance - 1 light technician - 1 sound technician after the last performance a/ strike 1 person b/ load-out 1 person day of 2nd and subsequent performances: a/ washing, dry cleaning and ironing of the costumes b/ performing rehearsal c/ cleaning of the dance floor